- This topic has 9 replies, 1 voice, and was last updated 8 years, 1 month ago by AME.
-
AuthorPosts
-
2nd December 2014 at 12:10 #69712AMEGuest
HOW CAN WE PATCH ON PRFILE IN NOKIA BSC?
3rd December 2014 at 15:54 #69713GazGuestZWOI to interrogate
ZWOC to change a parameter6th December 2014 at 11:46 #69714AMEGuestdear Gaz
i know,but you know that every parameter in wos and wos from two files in lfiles, fifilegx and prfilegx. some new feature has not any par in wos or woi so you had to load new prfile ,i mean how we can add a new feature to BSC WITH PATCHING FIFILEGX AND PRFILEGX .
7th December 2014 at 11:45 #69715GazGuestWhen you update the software with the macro, it updates the prfile and fifile.
After you take the new SW to default, you are working off new Prfile and fifile.
7th December 2014 at 11:59 #69716AMEGuestDEAR Gaz
thanks for your reply
consider we have just new prfile but all feature in this file is off you know if we load this file to bsc and restart all featue will be deactivated and need to activated all of them by WOA WOC BUT THIS TAKE SO MANY TIME AND AFFECT ON TRAFFIC ONE WAY IS GETTING FB AND LOAD NEW PRFILE TO IT AND PATCHING RELATED RECORD AND ACTIVE FB
MY QUESTION IS ABOUT THE WAY OF THIS PATCHING?8th December 2014 at 10:14 #69717GazGuestI dont really understand what you mean.
In the BSC there is FIFILE, PRFILE & PAFILE.
When you upgrade the BSC software using the Macro, it automatically takes the old parameters from these files and converts the same parameters into the new PRFILE.
What are you trying to do? Please explain clearly and maybe i can tell you how to do it.
8th December 2014 at 10:22 #69718GazGuestEven when you check inside the PRFILE or FIFILE with Text or Hex Editor, its impossible to know which line represents what.
So, you must use the conversion as used in the macro, PRFCNVGX Conversion.
Alternatively, just load the PRFILE & FIFILE into the BSC out of hours, and modify the parameters using a premade basic excel script. I dont this before, it takes 10 minutes to make excel to output all the commands and then just 2 minutes to throw the commands in.
You could then extract the PRFILE & FIFILE and copy them to another BSC.
15th August 2015 at 07:48 #69719AMEGuestWE HAVE SO MANY ALARM #1078 IN MCMU AND AFTER THAT AUTOMATIC MCMU SWITCHOVER AND THEN SYSTEM RESTART .HAVE YOU GOT ANY EXPERIENCE LIKE THAT?
16th August 2015 at 23:25 #69720GazGuest“WE HAVE SO MANY ALARM #1078 IN MCMU AND AFTER THAT AUTOMATIC MCMU SWITCHOVER AND THEN SYSTEM RESTART .HAVE YOU GOT ANY EXPERIENCE LIKE THAT?”
Most likely a software or hardware fault.
Would need further analysis.
Alarm history and check Computer logs to see if it gives you any clues.
Basic trouble shooting steps.
Do you get it for both MCMU or just the one MCMU?Possible Quick Fix – You know you have temperamental MCMU’s so you cant risk loosing two during busy hours. Out of hours lock individual down and reload the software to MCMU from DSK. Do the same to both of them one at a time.
11th December 2016 at 07:37 #69721AMEGuestHOW WE CAN ACTIVATE MULTIPOINT-GB IN NOKIA BSC?
-