Home » Topics » Telecom Design » TRX IDLE
Pet Guest
hi
I’ve a problem..I’ve a cell(RBS2216) with 2 TRX.. and the second TRX is always idle.. I tried to do a swap .. and still the second TRX idle. what can I do?
Jason Guest
If you have swapped the hardware, I would think this would be a parm issue.
Pet Guest
thank u very much Jonson for the reply, what are probably the parameters I shuld check?
THX
NJ Guest
Hi,
Try to lock the one TRX working, BCCH should jump to the other and see if there is traffic.
please send printout RXCDP, RLCRP
BR,
NJ
Pet Guest
THX NJ
I tried the idea of locking the 2nd TRX, the traffic tends to zero… is that mean the TRX is faulty?
pix Guest
pet,
yes, probably the trx. there is a remote chance that it is the bts itself or the digital module that is faulty, but i’d rather bet on the trx.
rgds
pix
Pet Guest
Thx Pix
I sent a request to change the TRX …But what did u mean by digital module?
pix Guest
PET,
I don’t know the name in E/// BTS. It’s the module that interfaces the BTS with the Abis, called SUM in ALU.
rgds,
pix
Pet Guest
Pix
In E/// the module that interfaces the BTS with the Abis is called DXU “Distribution Switch Unit”
BR/
pix Guest