BTS OPERATION DEGRADED,RSSI detected Rx signal difference exceeding threshold.how ican clear this alarm after reset the bts alarm disappear but it appear again after some time please somebody help
Hi This is basicaly VSWR alarm.If the RSSI valus between to antenna is >3db then this alarm apeares.
Check all the antenna connections in BTS if not resolved then check the VSWR value of RF cables.After rectify all VSWRs and loose connection of cable it will resolve.