    Fault Name: TX high temperature
    Related faults: SO TRXC I2A:11 – TX high temperature
    SO TRXC I2A:25 – TX max power restricted
    AO TX I1B:27 – TX max power restricted
    Description: The temperature of the PA transistors is supervised. At maximum component temperature, faults SO TRXC I2A:11 and SO TRXC I2A:25 are raised on TRXC and maximum TX output power is reduced by 2 dB.
    If the temperature is still over maximum component limit after 2 minutes, the maximum output power is reduced by another 2 dB.
    If the temperature is still over maximum component limit after 2 minutes more, the transmitter is automatically shut down and faults AO TX I1B:12 and AO TX I1B:27 are raised.
    The fault stays active until temperature stays below the limit for 5 minutes. The TX is then enabled and maximum output power is progressively increased.
    Possible reasons: Climate system failure – TRU dummies missing – high temperature outside the cabinet