    Please help to provide information on Reselect Hysterysis ? Which things & KPIs should be taken into a/c while planning this ?

    #60197
    Pix
    Guest

    Check the number of location updates in cells which are at the border between two LACs.

    If number is too high, increase the CRH.
    If increasing CRH has no effect, then you should consider re-designing your LACs.

    -pix

    #60198
    Fresher
    Guest

    thanks pix,is there any other parameter.

    #60199
    Pix
    Guest

    Fresher,

    There are 400 other parameters.
    But none of them will modify the behaviour of LAC borders.
    the cell reselect offset will be applied on all neighbours, instead of only the “other LAC” neighbours… but apart from that, the effect is comparable (favour/handicap other cells)

    both should be used in parallel.
    -pix

    #60200
    Arif
    Guest

    We have a very new site in our network, which is situatated at LAC border. One of the cells are showing High CSBR and SDBR. What parameters should I check to eliminate these problem. This is a ericsson site. Other LAC situted site is also ericsson. Please respond ASAP. It is affecting the BSC KPI as well as.