Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors

SDCCH assignment fail BSS rate

  • This topic has 3 replies, 1 voice, and was last updated 15 years ago by Pix.
Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #60138
    RF
    Guest

    Need your help in this indicator
    SDCCH assignment fail BSS rate after the site resetted this indicator increased from 65% to 85%.

    #60139
    Pix
    Guest

    Between 65% and 85% there is not much change : the cell is just not working. It wasn’t working, and it is still not working.

    To fix this problem, you can already assume that the problem lies in the Hardware.
    Try allocating the SDCCH TS in one TRX only. TRX1, then try in TRX2, then in TRX3, and so on. In each case, perform a call test and see if the problem is better (or just check SDCCH Assign Fail BSS %)

    Try also deleting the cell and recreate it from scratch… also try resetting the TCU/TSU.

    Regards,
    pix

    #60140
    RF
    Guest

    Thank you may i know what is tcu/tsu vendor is alcatel

    #60141
    Pix
    Guest

    RF,

    TCU/TSU is a BSC board. Ask your OMCR supervisor, he will know what it is and how to check it.

    -pix

Viewing 4 posts - 1 through 4 (of 4 total)
  • The forum ‘Telecom Design’ is closed to new topics and replies.