Rx Diversity Lost on Ericsson RBS 2206

  • This topic is empty.
Viewing 15 posts - 1 through 15 (of 19 total)
  • Author
    Posts
  • #58945
    Toby
    Guest

    I’m having Rx diversity lost alarm and anytime i work on it, it clears but comes back after a few days. What culd be the problem.

    #58946
    jamil
    Guest

    hi toby
    Or diplexer fault or vswr and some time jumper

    #58947
    saad
    Guest

    Faultu TRU

    #58948
    emreigrek
    Guest

    did you test sectors with crossing equipments? (tru,cdu,feeder,antenna,rx jumps)

    this alarm appears at least 50 minutes.

    #58949
    RK
    Guest

    You might be missing RX antenna. Please u can see at OMT radion faults that u miss the RX antenna. if u attach antenna i hope alarm will go off.

    #58950
    Rex
    Guest

    Hi Toby,
    do you have VSWR alarm too?

    #58951
    Toby
    Guest

    I’ve checked the antenna and all of them are connected. I just changed the Rx diversity of the antenna to Azimuth and the alarm cleared.
    I’m hoping it wont come back cos the only option i feel i have now is to change the CXU.

    #58952
    Emmanuel
    Guest

    Rx Diversity lost code

    #58953
    finn
    Guest

    do a test call around and check maybe you’ll pickup the wrong bcch on the wrong sector.. then rewire or redo jumpers

    #58954
    pban
    Guest

    Check / change the RX cables, may be with another sector, so that when the alarm comes in again, you know why.

    Remake the connectors at jumpers and feeders at both ends.

    #58955
    ENG.alaa
    Guest

    change the RX cable from sector to another sector and try to remake sure connector and jumper to Remove VSWR alarm

    #58956
    Toby
    Guest

    It was the CXU…I changed the CXU and the fault cleared permanently…

    #58957
    Rohit
    Guest

    I’ve been having Rx diversity problem with similar problem where DTRU,CDU,Feeder,Jumpers have been changed but still the alarm exit…Need help.

    #58958
    Rajan
    Guest

    Dear sir,
    I am facing the problem of antenna branch alarm-Branch-B in all sectors.
    It was found vswr values normal then also vswr alarms are pinging in my 10 sites on ericsson 3g RNS6202.
    Kindly guide me for alarm removal.

    #58959
    mohamed
    Guest

    how can get site coverage

Viewing 15 posts - 1 through 15 (of 19 total)