Hi Rcdece, I didn’t work on ericson equipment but I think that the difference is due to “power control” activation, so if you want to get the same value of Rx Lev in the two modes you have to disable it.
Which RxLev in dedicated mode? RxLev_Full or RxLev_Sub? If you have activated DTX then RxLev_Sub should be greater than RxLev_Full and nearly or equal with RxLev in Idle mode. I think that’s normal.
Regards,
If you use DTX, RxLev_Full has a value let’s say -91 dBm, RxLev_Sub greater than that let’s say -68 dBm, while in Idle mode RxLev_Full=-65 dBm. So, RxLev_Full (Idle) is aprox. equal with RxLev_Sub (Dedicated) and RxLev_Full (Idle) is about 26 dBm greater than RxLev_Full (Dedicated). Of course,not allways. Whenever DTX is used, you’ll have that difference.
Regards,
must be power control effect.we should remember that power can increase or decrease in power control process depends on the radio environment and parameter settings.
Hi,
RxLev in Idle mode in most cases are higher than Dedicated mode. Mainly due to the fact that Idle Mode Measurements are taken on BCCH frequency which is transmitting Max power at all time. While in dedicated mode, Measurements are normally taken at TCH chnnels ( Operators normally Prefer TCH channels as priority for traffic than the BCCH), plus the effect of BTS power control feature that has been mentioned already.
Thats normal, because of using dtx and dl- power control
When you disable it and disable Hopping (and Antenne hopping) it will be eaqal
But thats the reason for using RXLEV sub….
Author
Posts
Viewing 11 posts - 1 through 11 (of 11 total)
The forum ‘Telecom Design’ is closed to new topics and replies.