  • #56072
    RAY
    Guest

    Hi,

    we are getting inter msc(nokia) handover failure.external lac has been defined two mss and handover no. also routed.in one mss getting result”msc-bsc IF protocol error” ,

    and in another mss getting result “equipment failure”.

    please help..

    rgds
    ray

    #56073
    Himan
    Guest

    Check the external LAC definition in BSC side.And also check the cause code 1032 in EOS analysis which is having MAS. Probably tree-50 defined. Route the HON in tree-50.