Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors

HO success in one way

Viewing 15 posts - 1 through 15 (of 17 total)
  • Author
    Posts
  • #55046
    Antapé
    Guest

    Hi ALL

    i have couples of cells with one way ho success rate very low, my ho parameters are ok. please give solution!!!

    #55047
    pix
    Guest

    check preparation success rate and efficiency rate, check the cause of the failure (thanks to indicators in your PM Viewer) : congestion, radio BSS prep failure or BSS failure ?

    didn’t we have a discussion about this already ?

    #55048
    Antapé
    Guest

    Hi pix,

    the example of this problem:

    cell1 to cell2:100%ho success
    cell2 to cell1: 7%ho success

    with no congestion in cell1 and good ho success with other neighbours.

    The preparation is good also but the execution is bad.
    i think to decrease homarginlev in one sense since most of ho cause in cell2 is due to weak ul level. what do you think?

    #55049
    Johnson Crew
    Guest

    What could account for the difference in values between HO decision and attempts on an ericsson network?

    #55050
    pix
    Guest

    antapé,

    poor execution from cell 2 to cell 1 has nothing to do with congestion, but probably more with a broken TRX in cell 1

    what is the call setup success rate of cell 1 ?
    more precisely, what is the TCNAFLR (tch normal assignment failure rate) ?

    if cell 1 is working perfectly, then you should check the radio conditions in the area where MS are most probably doing the HO from cell 2 to cell 1. Check interference, or obstacles, that could stop the radio link suddenly. However, with 7% success rate, I would assume it’s more of a TRX hardware problem than a radio problem.

    #55051
    Antapé
    Guest

    HI pix,

    cell1 has 1.15% of tch assignment fail.I think it is not HW problem since other cell1 neighbours has successefull HO, only low HOSR with cell2.

    Thanks!

    #55052
    Pix
    Guest

    Ok, that’s a little strange… If you’re certain you don’t have any kind of interference, if you’re sure the coverage at the intersection of both cells is good, and finally, if you’re sure the HW is good (it looks like it is good) then the only possible issue is a kind of software bug.

    I’m sorry, I cant help anymore than this…

    #55053
    Evgen
    Guest

    Antapé, which type of HO from cell 2 to cell 1 (intraBSC, interBSC or interMSC)? Which HOSR on cell2 for outgoing HO to other neighbours.

    #55054
    krishnan
    Guest

    During drive test ,my voice call get muted for few seconds e whenever hand off takes place and then call get drop.Pl tell me the reaons.

    #55055
    Antapé
    Guest

    hi Evgen,

    it’s intraBSC ho, HOSR from cell2 to other very good. this is why i do not catch this problem.

    Thanks!

    #55056
    tranhung
    Guest

    we are using nokia BSS, problem with HOSR as:if “freq list is taken from the adjacent cells” HOSR get 95%- 96% only. When we create BA list include all freqs adjacent cells, HOSR increase to 98%. help me why?

    #55057
    Pix
    Guest

    Tranhung,

    I don’t understand the differences between the two choices…

    freq list is taken from the adjacent cells

    or

    we create BA list include all freqs adjacent cells

    Could you give an example of BA list?

    #55058
    tranhung
    Guest

    Hi Pix,
    I ask another question clearly:
    Parameter : “Measurement BCCH Allocation list” need set 0 or 1 Why?, what happen if set 1 or 0 ( We using BSC/BTS Nokia.
    Thank alot

    #55059
    Pix
    Guest

    Hello,

    your first question got an answer already ?

    for the second question, i still can’t answer: this parameter name doesn’t ring any bell (i don’t work with nokia system). Perhaps you can write down the description of this parameter? Its properties? Then I could tell you what it does.

    #55060
    Azzazi_RFoptimization_eng
    Guest

    Dear Antapé.
    you may do the following:
    1- check HO type from Cell2 to Cell
    2- check HO margin and hreqav between them.
    3- make drive test and ensure the HO conditions are satisfied in the field or not.
    4- you can delete the neighbor relation between them and redefine it again (maybe it is a software bug)

Viewing 15 posts - 1 through 15 (of 17 total)
  • The forum ‘Telecom Design’ is closed to new topics and replies.