Reply To: High SDCCH Assignment Failure

#53421
SA
Guest

Hello EugeZ.

You can try the following command on a BSC level in WinFIOL:

print var rmscs 94;

The Print will look something like this:

VARIABLE
RMSCS VAR H’05E=H’000E

With the hexadecimal value H’000E. You look for the decimal value, in this case 14. And use the following formula:

T3101 (decisecs) = ZINTERVAL x (CT3101 – 2) / 4

When you substitute the formula with ZINTERVAL=10 and CT3101=14, then the following value is obtained:

T3101 (dsecs) = 10 x (14 – 2) / 4 = 30deciseconds (3seconds)

The CCALLS and CMSESTAB are found in the dbo_CELL_MAIN table in the GRAN_seg1 (for example). In that very same table the counters CESTIMMASS and CESTCHACTIV are stored.

I hope this helps!