Try undertaking power checks of the sector. Many a times the reverse power in one of the TRX path causes the alarm, carry out checks at BTS top and antenna entry end.
All that this alarm is saying is that you have a difference between you main and diversity anttena lines. I have 5 years experience with Ultrasites and Talkfamily before that. The alarm parameter is set in your BSC so make sure that the parameter is not set to low usually less than 10dB of difference is acceptable.
Next if this parameter is set correctly go to your BTS and complete a return loss system sweep and make sure that your two lines that you are recieving on are passing to your spec on the uplink path. If they and you are using a tower mounted amplifier(TMA/LNA) make sure that it has the correct amp draw. One of these should more than likely be your problem. If not you may also check that all of the cableing inside your cabinet is correct and tight.
ALARM COMING THAT IS RX LEVEL DIFFERENCE BETWEEN MAIN AND DIVERSITY ANTENNA, ACTUALLY VSWR IS 1.26 IN MAIN AND IN DIVERSITY 1.32 BUT STILL ALARM IS COMING I SWAPPED THE TRX DUPLEXER AND ALL THE EQUIPMENT IN THE SECTOR EXCEPT GSM ANTENNA BUT STILL ALARM IS COMING I WANT TO KNOW WHY THE ALARM IS COMING