  • #41441
    aris
    Guest

    Hi,

    Can anyone provide me a help about RBS and BSC Ericsson? Especially any related commands and parameters.

    Thanks!

    #41442
    Tuan
    Guest

    Hi,

    There are a lot of commands and parameters related to Ericsson BSC/RBS .

    If you need the help in details, pls.let me know

    tuanvn@yahoo.com

    Brgs//Tuan

    #41443
    aris
    Guest

    Hi Tuan,

    Thanks for your reply. i really need your help on this. The details of my request is already sent to you using my yahoo account (ariscondino@yahoo.com0.

    Thanks in advance!!!

    Aris

    #41444
    Saidoo
    Guest

    also me i need the command

    dreem196@hotmail.com

    #41445
    Anjung
    Guest

    Hi Tuan,
    Are there any commands to read the alarm history in a rbs and also command to read the type of concentration mode, I mean LAPD unconcentrated, LAPD concentrated or LAPD multiplexing
    Thaks!

    #41446
    Mostafa
    Guest

    To Anjung

    Rxmop:mo=rxocf-tg; then go to sig parameter

    #41447
    Cege
    Guest

    Hi every body,

    Can anyone tell me how can i identificate a cell name when i know only dip number? What commands and parameters related to Ericsson BSC/RBS in Winfiol i have to use?

    Thanks for your help

    cgcamal@yahoo.com

    #41448
    Tuan
    Guest

    The command to read history alarm is : RXELP :Mo= XXX;

    #41449
    mugna69
    Guest

    If you have DIP/DEV data and you want to find cell names you can:

    – print all RXOTG values with

    rxapp:moty=all; (very long)

    – extract cell value with

    rxtcp:mo=rxotg-XX;

    OK?
    bye!

    #41450
    mugna69
    Guest

    sorry, the first comand is wrong, i mistyped it.
    the correct one is

    rxapp:moty=rxotg;

    #41451
    Cege
    Guest

    Thanks mugna69 for answer me.

    But don´t you know another shorter way to do that?

    For example a commamd or set of commands that get cell name knowing dip number, but only and directly for the cell that i need, because the print out of this command rxapp:moty=rxotg;
    is very long.

    I´ll appreciate any other suggestion.

    #41452
    Anjung
    Guest

    Hi all,
    What is the command to identity an RBS temperature inside? I can analize from external alarms (allip and allip:alcat=bts) but not accurate enough)

    Thanks !!

    #41453
    Carmelo
    Guest

    I need to know whether there are one or more phisical Ethernet sockets (RJ45) on Ericsson RBS 2202 or 2206, to be used to send information to the BSC, through the E1 Link.
    Many thanks.
    Carmelo

    #41454
    Amirul
    Guest

    Hi Cege,

    We use the cell name as dip name like dip name d16001 is adopted from the cell name d16001a/d16001b/d16001c.

    u can try this

    #41455
    nazar
    Guest

    iwant to Know how to get power measurment report come from specific Mobile terminal