Hi,
I am french, sorry but my english is not very good. I read a lot of post of this forum and i can see that tere are many experts of BSS.
I have an alarm on NOKIA’s ET
BCSU-8
* ALARM ET-83
1B120-25 ERDSUP
2990 V3 INTERFACE ALARM
ET 83d 05
What does it means. I see on NED but I don’t know to resolve.
This alarm came after to make a new BTS on this ET.
I have ET2E-S and BTS ultrasite connected. The PCM is correct signal.
Hi Patrick
Can you explain a little more on what you have done for this alarm.
In the command ZYEI there
UNIT FUNCTIONAL FRAME ALIGNMENT SA-BITS FOR
MODE MODE Q.1 USE
ET-32 NORM DBLF – V3 SPV OFF
ET-33 NORM CRC4 – V3 SPV OFF
Hi Patrick
Can you explain a little more on what you have done for this alarm.
In the command ZYEI there
UNIT FUNCTIONAL FRAME ALIGNMENT SA-BITS FOR
MODE MODE Q.1 USE
ET-32 NORM DBLF – V3 SPV OFF
ET-33 NORM CRC4 – V3 SPV OFF
I wanted a little more explanation on where to keep CRC4 or DBLF mode
Author
Posts
Viewing 4 posts - 1 through 4 (of 4 total)