    k. smith
    Guest

    Can someone give me average power and peak power loads of rbs 2206 and 2202? I am trying to design a solar hybrid power source for base station site in africa.

    #37751
    vijayaraj
    Guest

    for 2206 with 24V power is around 900w with 4+4+4 config.

    #37752
    anjung
    Guest

    RBS2202 with fully equipt (4+4+4)
    Max power consumption per RBS with power supply voltage
    +24VDC = 2100 W
    230VAC = 3200 W
    -48VDC = 2400 W
    Maximum heat generation = 2200 W

    #37753
    Naresh
    Guest

    Hello
    all i want know what is the current consumption (power consumption )of RBS 2206

    Pls reply

    #37754
    mostafa
    Guest

    – The maximum operating power consumption for RBS 2206 is :3855 Watts. ( Valid for 120-250 VAS)