- This topic has 76 replies, 1 voice, and was last updated 10 years, 4 months ago by charles m.
-
AuthorPosts
-
3rd December 2003 at 03:11 #37040MisaGuest
Hi all,
Could anybody pls help me, is there any dimensioning/planning calculation for SS7 signalling between switching nodes in the telecommunications network?
Any comment would be appreciated.
Regards
4th December 2003 at 21:15 #37041VijayGuestHi Misa,
For redendancy there should at least two signaling links between two switching nodes and
According to standards if u r using load sharing then per link load should not go beyond 40%.Regards.
5th December 2003 at 09:17 #37042PankajGuestMisa,
Ideally the SS7 signalling links dimensioning is done based on the message load. Meaning that you need to first findout what type of messages are being sent on the SS7 links. For each type of message, you need to know the messages length (Bytes) and what is the frequency of each type of message (that is generally dependent upon the BHCA). Once you know all this you only need to do the maths for bytes per second. If you have E1 then each link will be 64Kbps and if T1 then it will be 56Kbps. Devide the Bytes (hence K Bits)per second requirement with the link speed and multiply with 40%, and you have the total number of links.
If you are using the SS7 links for ISUP, a general rule of thumb is to have 40E1s, per pair of SS7 links.
6th December 2003 at 15:18 #37043MisaGuestHi Pankaj and Vijay,
Thank you very much for all of your information. I am interested in SS7 dimensioning not for ISUP only, but also dimensioning for IN network and GSM network that supports GPRS. How the IN network and GPRS will impact on the dimensioning of the SS& signalling? Do you have any idea on this matter?
Thank so much.
7th December 2003 at 18:27 #37044SunilGuestHi Pankaj,
Can you help me out to calculate the SS7 Load in AXE By usinng the C7 Statistics Report ?
Rgds
8th December 2003 at 09:48 #37045PankajGuestSunil, I can not advise you in that regard as i am not familier with AXE statistics.
Misa, The method that i explained you applies for any type of SS7 load (not only for ISUP) and even applicable for IN. I understand that this is not a very easy job as you need to know the details to it’s last byte, but in absense to any vendor specif tool, this is the only way to calculate the exact Traffic load. You will have to find out following items in order to be able to calculate
1- The IN BHCA
2- Number of messages between the HLR and MSC and IN because of IN, per BHCA
3- Messages length (number of bytes)of each message.and then you can apply the method as explained earlier.
9th December 2003 at 01:51 #37046MisaGuestPankaj
Thank you very much. I have seen something as a solution for the problem. Could you advise more specific, how to get the BHCA, how to get the number of messages between the HLR and MSC.
As far as I know, the messages length (number of bytes)of each message can be found in the SS7 document. Am I right?
Please help me to clarify these above questions.
Rgds
28th December 2003 at 11:04 #37047MisaGuestHi Pankaj and Vijay,
Could you give me an concrete example of calculation, or any document referred to this problem?
Any comment would be appreciated.
Thank you.
29th December 2003 at 15:29 #37048Eduardo SánchezGuestGreetings from Venezuela
Hi, I was wondering if any of you could help me in finding a way to monitor a ss7 link load.
I have been reading some and I always see a 0.2 or 0.4 erlang as reference points. Could you please explain to me why?
I will really appreciate any comments
12th January 2004 at 05:28 #37049prabhakar vermaGuesthi!..
since it is AXE 10 and you are working in GSM domain..
U can get all that information from your TMOS..
it is very Simple incase if you have TMOS or else search for C7 measurement in the ALEX and you will find the required step to do the Measurement.
The third and the last step is to connect an analyser say tektronics and put measurement or ASR or BHCA reports u want..13th January 2004 at 14:26 #37050KumarGuestHello Prabhakar Varma,
I am working with AXE10.
If possible Can you help me out with C7 Mesaurementy Reports.
We have hourly report.So how can I calculate the Load and utilisation.
Rgds
Kumar
19th January 2004 at 11:54 #37051prabhakarvermaGuestrun an isql query in the Tmos server.. you will get everything u want in a nice excel format..
20th January 2004 at 10:46 #37052KumarGuestHello Mr.Varma
We have TMOS but not Loca.
It is in our NMC.
Our OMC Directly generates the report and Feeds in a AFFILE.
Thatswhy I have asked you.
From that report how can I determine the Load,with which parameters.Rgds
Kumar
28th February 2004 at 07:51 #37053KevinGuestHi Every body
Pls tell me the formula of Erlang to calculate the capacity of a E1 with a blocking of 2 %?
15th September 2004 at 10:33 #37054murtala s usmanGuesthi all,
iam enquiring about the best protocol analyser that would enable me monitor calls from any type of networks.my preference is a universal analyser that would work with AXE-10,ALCATEL S12,and SIEMEN’S EWSD.Regards
-