Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors

VLR capacity in Siemens D900

Viewing 13 posts - 1 through 13 (of 13 total)
  • Author
    Posts
  • #36736
    hoangktnv
    Guest

    Hi all/
    i have some question need ur help :
    – how to see VLR capacity in Siemens D900 switch
    – the relation betwween VLR capacity with CP load, traffic, trunk, c7 … in case i want to increase (expand)VLR ‘ capacity

    thanks in advance

    #36737
    amberish trivedi
    Guest

    hi hoangktnv

    u can get vlr capacity in ur report which is genrated form switch.we are calling it msc template.as ur vlr capacity will increase ur cp load may increase and traffic will also increas.
    to expand u have to must do software upgradation which can be done by patching load which will be provided by siemens person.
    if still doubt the ask without hesitation

    #36738
    hoangktnv
    Guest

    thanks for your kind.
    i mean how to know the maximum vlr capacity ( maybe via command in MSC).
    plz show me which commmand and which parameter to know maximum VLR capacity tin Siemens switch

    thanks again

    #36739
    erox
    Guest

    Hi!

    Using DISPDBSIZE command you can see all ODAGEN element and their percentage of use. VSD parametar points to VLR memory size.

    Best regards!

    #36740
    Nguyen
    Guest

    Hi guys,

    How about the command for MSC/VLR capacity in AXE-10 system?

    Thanks

    #36741
    Scot
    Guest

    In AXE you have to check a block Size which is responsible for holding dynamic subscriber data.

    The corresponding block is MTV.

    SAEEP:SAE=36;

    There it will Show the Maximum/100 & Current/100

    Rgds

    Scot

    #36742
    hoangktnv
    Guest

    thanks Erox for your kind,
    i found in my ODAGEN with VSD=2000, its mean is 2000 X 100 = 200.000 subs max in VLR ? OK?

    and i still dont know the meaning of another group besides VSD parametter (for ex., group ABB, ACB ….) althought i have found all D900 document.
    Thanks

    my mail : hoangktnv@yahoo.com

    thanks again

    Hoangktnv

    #36743
    erox
    Guest

    Meaning of other groups in ODAGEN you can ask only from Siemens personal who is responsible for it. Unfortunatelly, I don’t have any information about other ODAGEN groups.
    That for VSD group is right!

    rgds

    #36744
    facre
    Guest

    version française de la documentation sur votre systémé siemens version D900 sr9

    #36745
    hoangktnv
    Guest

    hi Facre,
    Plz say it into English
    i dont know france…
    thanks for your kinds

    #36746
    hoangktnv
    Guest

    yes, version of Siemens 900 is SR9

    #36747
    carlos
    Guest

    in ericsson AXE, u can try MTVRP command. It will show all users y VLR. But it takes long time (hours) to show the printout.

    #36748
    Scot
    Guest

    I never seen such a command MTVRP in AXE For the last 6 Yrs ?

    Rgds

Viewing 13 posts - 1 through 13 (of 13 total)
  • The forum ‘Telecom Design’ is closed to new topics and replies.