Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors

Capacity calculation

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #32842
    Raymond
    Guest

    A customer says that he plans to pass 1,000,000 minutes of traffic per month.

    Is there a rule of thumb to give a rough estimate as to how many ports he will need?

    #32843
    Igor
    Guest

    Hi Raymond,

    If this is the only information you have than you have to make some assumptions. You have to estimate the highes traffic he is going to offer to the network, i.e. BH traffic.

    We could say:
    1,000,000 min in 30 days (remember that these days include weekends when traffic is usually lower).

    1,000,000/25 = 40,000 min in 1 day (I divided by 25 and not 30 in order to compensate for weekends. The value is from my experience for Telephone networks).

    40,000 * 12% = 4,800 min in Busy Hour (12% is also rather traditional value for telephony).

    4,800 / 60 = 80 Hours = 80 Erlangs.

    Here you have to use Erlang-B calculator. The input is 80 Erlangs and the GOS you want the customer to have, lets say 2% blocking. So we get 92 lines.

    Good luck with making telecom business and have fun! 🙂

    Best regards
    Igor

    #32844
    tasha
    Guest

    Can I use an Erlang calculator to work out how to get to a certain service level target?

Viewing 3 posts - 1 through 3 (of 3 total)
  • The forum ‘Telecom Design’ is closed to new topics and replies.