-Install this and do not enable any filtering.
This should be installed on a PC connected to the same HUB as either the Cisco or other VoIP end-point.
-Start Agilent by hitting the upper Green StopLight
-Place the call again while capturing the packets. Once the call is complete stop Agilent.
You really need to know what you’re looking for here, so if you don’t have a clue of what i’m getting at here let me know.
Issue:
Audio Connection times. It appears that one of the devices isn’t allowing audio from the far end to connect to allow RBT(Ring Back Tone).
try disabling inband tone from the non-cisco gateway. That might solve the problem – at least you will not be needing to activate Progress indicator in cisco…